Choosing ALUMINUM FOIL VENTILATION DUCT: Application Fit and Specification Checks

A buyer-focused guide to selecting ALUMINUM FOIL VENTILATION DUCT from Hebei Kebing Import and Export Trade Co., LTD. It covers the published construction, diameter and roll-length options, wall and steel-wire thickness, the -20℃ to +100℃ temperature range, and listed weights. It also explains when this duct may not fit and which points to confirm before ordering.

Choosing ALUMINUM FOIL VENTILATION DUCT: Application Fit and Specification Checks
AI-generated illustration; not a real product photograph, specification, operating permission or test certificate.
01

Operating temperature: the published heat resistance is -20℃ to +100℃. Applications outside this range are not covered.

02

Diameter fit: the published table lists I.D. sizes from 2" (50 mm) to 20" (500 mm). The summary range is 51–450 mm, so confirm the exact size.

03

Roll length: 10 m per roll for every listed size.

04

Wall construction: double-layer reinforced aluminum foil and fire-resistant glass fiber cloth, supported by a spiral of high carbon steel wire.

05

Tube thickness of 0.5 mm and steel wire thickness of 0.8–2.0 mm. The wire gauge for each size needs confirmation.

06

Support load: Weights per piece run from 2 kg (2") to 9 kg (16").

07

Documentation needs: no fire rating, leakage, insulation test data, certifications, prices or lead times are published. Request these separately if your project requires them.

When you buy flexible ventilation duct, start by checking the published specifications against your system. Don't start from the product name alone. This guide uses the confirmed product description of the ALUMINUM FOIL VENTILATION DUCT supplied by Hebei Kebing Import and Export Trade Co., LTD. It shows what the published data covers, how to compare it with your requirements, and where you need written confirmation before you place an order.

1. Define your buyer constraints first

Write down these operating conditions before you compare duct options:

  • Air or medium temperature at the duct, including seasonal lows and process highs.
  • Connection diameter (I.D.) of fans, collars, diffusers or equipment outlets.
  • Run length and how many rolls or pieces you will need.
  • Support conditions: how much load brackets and hangers can carry.
  • Project requirements such as fire ratings, building codes or test reports in your target market (for example the United States, the Middle East, Europe or Southeast Asia).

The published data answers some of these points directly. Others need confirmation from the supplier.

2. Construction: what the duct is made of

The product description lists this construction:

  • Aluminum foil + fire-proof glass fiber cloth + high carbon steel wire
  • A double-layer wall made of reinforced aluminum foil and fire-resistant glass fiber cloth
  • An inner spiral of high-strength tension steel wire that supports the wall

For buyers, this means a flexible duct with a foil-faced, fabric-reinforced wall held open by a wire helix. The description calls the glass fiber cloth "fire-resistant" or "fire-proof," but the material set includes no fire-rating standard, test report or certification. If your project requires a specific fire classification, ask for documentation before you treat that wording as compliance.

3. Dimensional specifications to check

ParameterPublished value
Tube (wall) thickness0.5 mm
Steel wire thickness0.8–2.0 mm
Size range (summary)51 mm–450 mm
Roll length10 m per roll for all listed sizes

The published size table lists these inside diameters and weights:

Size (inch)I.D. (mm)Length (m/roll)Weight (kg/piece)
2"50102
2-1/2"63102.2
3"75102.5
4"100103.2
5"127104
6"152104.5
7"18010
8"200106
10"250106.3
12"300107
14"350108
16"400109
18"45010
20"50010

Points to confirm: The summary size range (51–450 mm) and the table (50–500 mm) don't match. Weights for the 7", 18" and 20" sizes are not published. The data also doesn't say which steel wire thickness goes with which diameter. Confirm the exact I.D., wire gauge and weight for your size in writing before ordering, especially at the smallest and largest diameters.

4. Temperature range: the main application filter

The published heat resistance is -20℃ to +100℃, which the description presents as suitable for four-season use. Use this as a firm screening rule:

  • Within range: general ventilation or exhaust where duct temperatures stay between -20℃ and +100℃ may fit this product.
  • Outside range: if the air, exhaust or surrounding area can go below -20℃ or above +100℃, even briefly, this recommendation does not apply. Look for a product with documented ratings for those conditions.

5. Performance claims and how to weigh them

The product description makes these claims:

  • Thermal insulation: the duct is described as having good thermal insulation performance and as energy-saving.
  • Air-tightness and hygiene: a smooth aluminum foil surface with very low air leakage is said to keep conveyed air clean and avoid secondary contamination.
  • Weight: the duct is described as about 10% of the weight of iron air ducts, which reduces the load on brackets and hangers.

These are the supplier's own descriptions. No leakage rates, thermal values or test methods are published. If your design depends on a specific insulation value, leakage class or hygiene standard, ask for supporting data. For hanger planning, the per-piece weights in the table are more useful than the percentage comparison.

6. When this recommendation does not apply

The ALUMINUM FOIL VENTILATION DUCT may not suit your project if:

  • Operating temperatures fall outside -20℃ to +100℃.
  • You need a diameter outside the table, or a roll length other than 10 m.
  • Your project requires certified fire, smoke or insulation ratings and the supplier cannot provide documents.
  • You need published pressure, airflow or leakage values. None are included in the confirmed material.

7. Before you request a quotation

Prices, lead times, minimum order quantities and certifications are not covered in the confirmed material. When you contact Hebei Kebing Import and Export Trade Co., LTD, include:

  1. The required I.D. (inch and mm) and the quantity in rolls.
  2. Your operating temperature range.
  3. Your preferred steel wire thickness, if any, within 0.8–2.0 mm.
  4. Any fire-rating, code or test documents your market requires.

Matching these points to the published specifications helps you decide whether the ALUMINUM FOIL VENTILATION DUCT fits your application before you commit to an order.

THE COMPANY

Hebei Kebing Import and Export Trade Co., LTD

Ketong has focused on the professional hose, The company integrates production, sales, and scientific research into a new high-tech, polymer composite material plastic product manufacturer. The resin hoses produced by our company include pneumatic hoses, high-pressure hoses, air hoses-fluid hoses, garden hoses, fire hoses, steel wire hoses, plastic hoses, suction hoses Hundreds of varieties of dust pipes, ventilation pipes, etc; With more than a decade of experience in foreign trade, we are committed to strict…

About Us ↗Visit company website ↗

YOUR NEXT STEP

Bring your brief. Start a useful conversation.

Use case, specification, quantity and delivery window: make the next conversation specific.

Share


HOT PRODUCT
INQUIRE

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.